Skip to content

Scanner (Scan View)

The Scan View records the serial number of each PV module at its position within the string. This way each physical panel is linked to its serial number for plant traceability and for cross-referencing with factory data (flash test) and with anomalies.

Available in Thermal + Scanning projects: from the camera icon on the project card, the table menu (Scan View) or the breadcrumb dropdown.

Permissions

All users with access can see the scanning progress. Scanning and deleting serial numbers requires editing permission. Manage Keys requires AI tools. See Roles and permissions.

Before scanning

The project's strings must have their modules defined (number of slots, orientation and expected serial number length). If clicking a string shows the warning String … has no generated modules, its modules aren't prepared yet: contact the project's manager.


The map

The base map is the one you choose in Account › Settings › Map › Map style (satellite by default).

Each string is colored according to its progress:

Default color Status When
Blue Pending No module has a serial number
Orange Partially scanned There are serial numbers, but some are missing or don't have the expected length
Green Fully scanned Every module has a serial number with the expected length (S/N Digits; if the string has none defined, any number is valid)

The string colour only depends on the scanned serial numbers and their length: duplicated numbers and factory data (flash test) don't change it.

From zoom level 18 the labels with each string's ID are shown (Map Settings › Markers Visibility). In Map Settings you can also choose the background orthophoto and the strings' opacity.

Selecting a string and a module

  1. Click a string: the map zooms in, the string splits into its modules and the side panel opens (on mobile, a bottom panel that can be raised or lowered).
  2. Click a module on the map or in the Modules list to select it (it's highlighted in orange).

Module colors: green = valid serial number (Scanned), orange = incorrect length (Wrong scan), blue = empty (Not scanned). The panel's Modules list uses the same states as the background of each row. At high zoom levels each module's number is shown.

Changing the colours

The colours of module and string states are changed in Account › Settings › Map › Scan status colors. States you don't change keep the colours on this page.

The panel shows:

Element Description
Header String name and Scan Status (scanned / total)
Single Scan / Auto Scan Scanning mode
AutoScan Direction Direction of automatic scanning
Input mode Camera, external scanner or keyboard
Modules Module N: serial number list. The trash icon deletes a module's number
String data details Row, Combiner Box, String, Orientation, number of modules and expected digits (S/N Digits)

Scanning modes

Mode How it works
Single Scan Saves the selected module's number and stops
Auto Scan After saving a module, automatically moves to the next one in the chosen direction until the end of the string

In Auto Scan choose the direction: First → Last (from module 1 to the last one) or Last → First. Scanning starts at the first module in that direction.

Each serial number is saved on its module, so the scanner and the Project Dashboard Modules tab always show the same data.

Input modes

Select a module first; then choose one of the three buttons:

Camera

Opens the phone or tablet's rear camera. Frame the barcode inside the white box: once it's read steadily the box flashes green and the number is saved. The red button closes the camera.

Note

The camera reads Code 128 barcodes, the usual format on module labels.

External scanner (USB or Bluetooth)

For readers that work as a keyboard. With this mode active the application waits for readings (Waiting for external scanner...): each reading ending in Enter or Tab is saved to the selected module.

Manual

Opens Manual Barcode Entry: type the number in Barcode S/N and click Save (or Enter).

Overwriting

Saving to a module that already has a number replaces it without asking, and saving an empty field deletes it. Check the selected module before scanning.

Deleting a serial number

Click the trash icon for the module in the list and confirm in Confirm Deletion. The module's slot remains empty.

Manage Keys

Requires AI tools. Desktop only.

Rename Data Fields lets you rename the selected string's attributes and change their values (for example the orientation Vertical (V) / Portrait (P) or the expected digits). Click Apply Changes and reload the page to see the changes.

System fields

Don't rename id, orientation, digits, ROW, CB or STRING: the scanner needs them to function.

Tips

  • Work string by string and check the Scan Status before moving to the next one.
  • An orange string or module indicates numbers with a length different from expected: check them.
  • The overall progress and duplicate numbers can be found in the Modules tab of the Project Dashboard.